通告描述:
<p>This standard specifies: a) the field of application for pillar taps, bib taps, single and multi-hole combination taps for use in: 1) a supply system of Type 1 ; 2) a supply system of Type 2 (b) the dimensional, leaktightness, pressure resistance, hydraulic performance, mechanical strength, endurance and acoustic characteristics of nominal size ½ and ¾ single taps and combination taps; c) test methods to verify the characteristics. d) the tests described in this Standard are type tests (laboratory tests) and not quality control tests carried out during manufacture. This Standard applies to draw-off taps (single taps and combination taps) for use with sanitary appliances installed in rooms used for bodily hygiene (cloakrooms, bathrooms etc.) and in kitchens, i.e. for use with baths, wash basins, bidets, showers and sinks. Figure 1 shows a supply system of Type 1 with a pressure range of (0,05 to 1,0) Mpa [(0,5 to 10) bar]. Figure 2 shows a supply system of Type 2 with a pressure range of (0,01 to 1,0) Mpa [(0,1 to 10) bar]. This Egyptian Standard applies to sanitary draw-off taps of nominal size ½ and ¾ (PN 10). The conditions of use and classifications are given in Table 1 according to this standard.</p><p>Worth mentioning is that this standard complies with EN 200/2008.</p>
文档编号:
G/TBT/N/EGY/110
查看文档:
原文文档 翻译文档通告目的:
Protection of human health or safety (TBT)
相关产品:
Sanitary tap ware